Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) - Continued
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) - Continued

Power Plant An/Mjq-18 (Nsn 6115-00-033-1398) (2) Mep-003A 10Kw 60Hz Generator Sets M103A3 2-Wheel, 1-1/2 Ton Modified Trailer Page Navigation
  16    17    18    19    20  21  22    23    24    25    26  
img
ARMY TM 5-6115-633-14&P
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) - CONT.
W Weekly
M - Monthly
A - After
D During
B - Before
Item to be inspected.
Procedure: check for and
Interval
Equipment is not
have repaired, filled, or
Item
ready/available if:
adjusted as needed
no.
GENERATOR SET GAGES AND
21
INSTRUMENTS CONT
c.  Check that current meter (28) reading
does not exceed 100% or more than 5%
load difference between phases.
Desired voltage can-
Check that voltmeter (29) indicates
d.
not be obtained and
desired output voltage as deter-
maintained.
mined by load connections and amps-
volts transfer switch.
Oil pressure drops
Check engine oil pressure gage (30)
e.
for 20 to 45 psig indication.
below 20 psig.