Power Plant An/Mjq-18 (Nsn 6115-00-033-1398) (2) Mep-003A 10Kw 60Hz Generator Sets M103A3 2-Wheel, 1-1/2 Ton Modified Trailer Page Navigation
  15    16    17    18    19  20  21    22    23    24    25  
img
ARMY TM 5-6115-633-14&P
Table 3-2. Operator/Crew Preventive Maintenance Checks and Services (PMCS) - CONT.
D During
B - Before
A - After
W Weekly
M Monthly
Item to be inspected.
Interval
Procedure: check for and
have repaired, filled, or
Item
Equipment is not
no.
adjusted as needed
ready/available if:
●
19
BRAKE SYSTEM
Test brake system by hooking trailer
Service brakes fail to
to towing vehicle and applying brakes.
operate.
●
TRAILER OPERATION
20
a. Be alert for any unusual noises while
towing trailer. Stop and investigate
any unusual noises.
b. Ensure that trailer is tracking/following
correctly behind towing vehicle with no
side pull.
●
21
GENERATOR SET GAGES AND INSTRUMENTS
a.
Check that battery indicator (26)
Battery indicator not
is in yellow area while batteries
in correct area.
are charging and in green area when
batteries are fully charged.
b.
Check that frequency meter (27)
Correct frequency
i n d i c a t e s 60 Hz (red line) when
c a n n o t be obtained
generator is operating under load.
and  maintained.