TM5-6115-593-34
NAVFAC P-8-631-34
TO-35C2-3-463-2
Figure 11-9. Obtaining Dimension Y
(b)
Install permanent magnet rotor (37, figure 11-3)
with spring pin (36), cover (30), bolt (34), and
washer (35).
(c)
Install permanent magnet stator (33) with screws
(31) and washers (32).
(d)
Install cover (30) with screws (26 and 28), washers
(29) and nuts (27).
(e)
Connect (+) and (-) leads from generator field onto
(+) and (-) terminals located on the heat sinks of the
rotating rectifier assembly.
(f)
Before placing generator set in operation, visually
inspect clearance between generator stationary and
rotating parts.
(g)
Visually inspect alignment of the exciter armature
with the exciter field.
(h)
Before placing generator set in operation, turn
engine through several revolutions, but do not
permit engine to start. visually inspect clearance
between generator stationary and rotating parts.
Listen for
11-18