TM5-6115-593-34NAVFAC P-8-631-34TO-35C2-3-463-2Figure 11-9. Obtaining Dimension Y(b) Install permanent magnet rotor (37, figure 11-3)with spring pin (36), cover (30), bolt (34), andwasher (35).(c)Install permanent magnet stator (33) with screws(31) and washers (32).(d)Install cover (30) with screws (26 and 28), washers(29) and nuts (27).(e) Connect (+) and (-) leads from generator field onto(+) and (-) terminals located on the heat sinks of therotating rectifier assembly.(f) Before placing generator set in operation, visuallyinspect clearance between generator stationary androtating parts.(g) Visually inspect alignment of the exciter armaturewith the exciter field.(h) Before placing generator set in operation, turnengine through several revolutions, but do notpermit engine to start. visually inspect clearancebetween generator stationary and rotating parts.Listen for11-18