TM 5-6115-585-34
NAVFAC P-8-623-34
TO 35C2-3-455-2
TM05684C/05685B34
CAUTION
When drilling holes, care must be
taken not to damage control
cubicle.
(2) Refer to figure 10-4 and locate rear closure as-
sembly (1) behind mounting brackets (3).
Seat clips (3A) of rear
closure assembly (1) over mounting brackets (3), so that rear
closure assembly (1) is positioned over vibration mount hardware.
When positioned correctly, the rear closure assembly (1) is 1/4
inch higher than top of control cubicle (2).
Using rear closure
assembly (1) as template, mark and drill four 5/16 inch holes in
mounting brackets (3).
(3) Cut a 23 in. length and a 14 in. length of
adhesive backed teflon tape (as listed in Table 10-1, item 5).
Apply adhesive backed teflon tape to a clean top edge (edge with
three holes) and right edge (edge with two holes which will
contact right panel assembly) of rear closure assembly (1).
Use
hand pressure to remove air bubbles. Clear tape from holes.
(4)
Install rear closure assembly (1) to control
cubicle support (3) with four screws (5), eight washers (6 and 7)
and four locknuts (8) (as listed in Table 10-1, item 5).
(5)
Torque screws (5) to 16 ±2 ft-lbs dry.
(6) Refer to Operator and Organizational Maintenance
Manual, paragraph 3-18, and install air cleaner assembly removed
in step e. (1).
f.
Exhaust Plenum Assembly.
(1)
Refer to figure 10-4 and install exhaust elbows
(9) (as listed in Table 10-1, item 7) to generator exhaust (10).
Point elbow openings downward (exhaust down).
(2)
Install hose (11) over sleeve (12) at bottom of
exhaust plenum (13).
Install clamp (14) over hose (11) and
sleeve (12).
(3)
Install exhaust plenum assembly (13) over exhaust
shutter assembly (15) until rear upper channel of plenum is flush
with exhaust shutter assembly (15).
Screws (15A) in exhaust
shutter assembly (15) fit into plenum slots.
(There will be 1-
7/8 inch over-lap.)
Using exhaust plenum assembly (13) as
template, mark mounting holes (16) and drill four 5/16 inch holes
in exhaust shutter assembly (15).
10-10
Change 6