TM 5-6115-545-12
TO-35C2-3-444-1
NAVFAC P-8-626-12
TM-00038G-12
Table 3-1. OPERATOR/CREW PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Cent)
B BEFORE OPERATION
D DURING OPERATION
A AFTER OPERATION
ITEM
NO.
2
INTERVAL
B
l
l
D
l
A
ITEM TO BE
INSPECTED
Batteries
Fuel Selector Valve
Controls and instruments:
a.
b.
c.
d.
e.
f.
g.
Battery charging
ammeter
Coolant temp gage
Voltmeter
Oil pressure gage
A.C. ammeter
Wattmeter
Frequency meter
PROCEDURES
Remove corrosion and apply grease
to cable connectors. Tighten loose
cables and mountings. Inspect for
cracks and leaks. Fill batteries to
3/8 inch above the plates. Clean
vent hole in filler cap before instal-
ling. In freezing weather run engine
a minimum of 1 hour after adding
water.
Turn fuel selector valve to the
correct position.
Instruments shall indicate within
specified limits. (Fig. 2-5)
Green portion of scale
180° to 200° F
120/208 - 240/416
30 to 55 psi
Indicates percentage of applied
current. Not to exceed 100%
Indicates applied load. Not to
exceed 100%.
400 Hz - 50/60 Hz
EQUIPMENT WILL
BE REPORTED NOT
READY (RED) IF:
Cable connections
cannot be tightened,
or battery is cracked
or leaking.
Fuel selector valve is
inoperable.
Ammeter does not
indicate charging
current.
Temp exceeds 200° F.
Voltage cannot be
properly adjusted.
Pressure is below
30 psi.
Meter is
nonfunctional.
Meter is
nonfunctional.
Frequency cannot be
properly adjusted.
3-8
Change 13