TM 5-6115-465-12
TO 35C2-3-446-1
NAVFAC P-8-625-12
TM 06858B/06859D-12
(3) Inspect electrical wiring for loose ter-
corrective action taken on the applicable forms
minals or connectors, burned or frayed insulation,
at the earliest opportunity. Army and Navy users
loose support clamps and other damage.
shall accomplish the necessary preventive main-
tenance services listed and described in sub-
(4) Check coolant lines for loose connections,
paragraph b. below. Air Force users shall refer
to the applicable inspection manual and work card
sets in the T.O. 35C2-3 Series for periodic re-
quirements and table 4-1 for detailed procedures.
b. Service.
Marine Corps users should refer to the current
issue of TM 11275/1.
(1) Loosen fasteners and remove protective
b. Preventive Maintenance Checks and Ser-
vices. (Army and Navy).
(2) Disconnect burner fuel line (2) and re-
(1) Operator. Table 4-1 contains a tab-
move metering orifice assembly (3).
ulated listing of preventive maintenance checks and
services which shall be performed before, during,
(3) Remove filter body (4) with gasket (5) and
and after operation and the weekly checks and ser-
sintered filter (6) from heater assembly (7).
vices to be performed by the operator. The item
numbers are listed consecutively and indicate the
sequence of minimum requirements. Refer to table
(4) Unscrew sintered filter (6) from filter
4-1 for checks and services.
body (4). Discard gasket (5).
(2) Organizational Maintenance. Table
(5) Clean metering orifice assembly, screen,
4-1 also contains a
tabulated listing of
preventive
and sintered filter in an approved solvent and dry
maintenance checks and services which shall be
with filtered compressed air.
performed by organizational maintenance personnel
at monthly and semi-annual intervals. The item
numbers are listed consecutively and indicate the
(6) Hold orifice up to a light and check to
sequence of minimum requirements. Refer to table
make sure its pin hole is unobstructed.
4-1 for checks and services.
(7) Screw sintered filter (6) into filter body
(4) and install with new gasket (5) into heater assem-
bly.
Table 4-2 contains a
list of
malfunctions which
is useful in diagnosing and correcting unsatisfactory
operation or failure of the fuel burning winterization
CAUTION
kit. Each malfunction is followed by an alphabetical
listing of probable causes of the malfunction. The
Use extreme care when installing the
corresponding alphabetical listing of corrective
orifice assembly. Its pin hole can
actions contains references to applicable mainten-
easily be clogged by any small particle
ance paragraphs for correcting the malfunction.
of foreign matter.
The table lists only those malfunctions, probable
causes and corrective actions wbi ch are within the
scope of organizational maintenance. Any malfunc-
(8) Install orifice assembly (3) and connect
tion whose corrective action is beyond the scope of
burner fuel line (2).
organizational maintenance shall be reported to
higher level maintenance.
(9) Install protective cover (1) and tighten its
fasteners.
4-7. OPERATOR INSPECTION AND
SERVICE OF
FUEL BURNING WINTERIZATION KIT.
ORGANIZATIONAL MAINTENANCE OF FUEL
BURNING WTNTERIZATION KIT.
a. Inspection.
(1) Visually inspect heater assembly (4, fig-
Heater Control Assembly.
a.
ure 4-1) for insecure mounting, dents, cracks,
corrosion, and other damage.
(1) Removal.
(2) Inspect fuel lines for cracks, breaks,
loose connections and support clamps and other dam-
(a) Remove screws (figure 4-3) and wash-
age.
ers.