MALFUNCTION
PROBABLE CAUSE
CORRECTIVE ACTION
Press-to-test
a. Discharged batteries.
a. Recharge or replace batteries (para.
indicator does
not light when
b. Circuit breaker open.
pressed
c. Defective control assembly.
Heater control
a. Circuit breaker open.
switch placed in
b. Discharged batteries.
b. Replace or recharge batteries (para.
ON position but
heater does not
start
c. Defective wiring harness.
c. Replace damaged wiring harness
d. Defective control assembly.
a. Heater fuel shutoff valve
Blower operates
but heater does
closed.
not ignite
b. Generator set fuel supply
exhausted.
c. Restriction in fuel supply line.
c. Remove fuel line restriction.
d. Defective thermostat switch.
d. Test thermostat switch. Replace if
e. Defective igniter assembly.
e. Inspect and test igniter assembly. Re-
f. Regulator valve assembly
f. Service regulator valve assembly
screen, sintered filter or
metering orifice clogged.
g. Generator set fuel transfer
g. Replace fuel transfer pumps (para.
pumps defective.
Surging heater
a. Restriction in fuel line.
a. Locate and remove restriction in fuel
line.
b. Replace fuel transfer pumps (para.
transfer pumps.
c. Defective igniter assembly.
c. Inspect and test igniter assembly.
Flame switch out of adjustment.
continues titer
heater control
switch placed in
OFF position.
Heater does not
Flame switch out of adjustment.
complete purge
cycle
Fan continues to
a. Flame switch out of adjustment.
operate after
purge cycle
b. Incorrect wiring connections.
b. Check wiring for improper connections.