TM 5-6115-465-12
NAVFAC P862512
TO-35C2-3-446-1
TM 06858D/06858D-12
(1) Removal and Disassembly.
(b) Visually inspect base for cracks, corrosion,
stripped or otherwise damaged threads, and evidence of
(a) Tag and disconnect electrical leads to syn-
shorting.
chronizing light assemblies.
(c) Inspect lamp for cracked or broken
glass, corrosion, and burned out filament.
(d) Check lens for cracked or broken
rhronizing light assemblies (108).
glass, cracks, and stripped or otherwise damaged
threads.
(c) Unscrew lens (109). Depress lamps
(110) and rotate countercloclnvise to remove from
(e) Replace any damaged or defective
bases (111).
parts.
(2) Cleaning and Inspection.
(3) Installation. Install indicator light as-
sembly in reverse order of removal procedures.
(a) Clean synchronizing light assemblies
with filtered compressed air and a sotl bristle
brush or wipe with a clean, lint-free cloth lightly
NOTE
moistened with an approved solvent.
Air cleaner condition and battle short
(b) Visually inspect bases for cracks,
indicator lights have red lens. Circuit
corrosion, stripped or otherwise damaged threads,
breaker indicator light has amber lens.
and evidence of shorting.
(c) Inspect lens for cracks, breaks, and
FAULT LOCATING INDICATOR.
stripped or otherwise damaged threads.
a. Inspection. Inspect fault locating indicator
(d) Inspect lamps for corrosion, cracked
for cracks, corrosion, cracked or broken indicator
or broken glass, and tmrned out filament.
light lens, missing hardware and other damage.
(e) Replace any damaged or defective
b. Testing. Depress test or reset switch and
parts.
check that all indicator lights are lit.
(3) Assembly and Installation. Assemble and
c.
Lamp Replacement.
install synchronizing light assemblies in reverse
order of removal and disassembly procedures.
lamp.
y. Air Cleaner Condition, Circuit Breaker and
Battle Short Indicator Light Assemblies.
(2) Visually inspect lamp for corrosion,
cracked or broken glass, and burned out filament.
(1) Removal.
(3) Replace lamp if defective.
(a) Tag and disconnect electrical leads to
indicator light assemblies.
(4) Install lamps and lens.
d.
Fuse Replacement.
2 of 3). Press in and rotate counterclockwise to re-
move lamps (113).
fuse.
(c) Remove nuts (114) to remove bases
(2) Visually inspect fuse for corrosion,
cubicle assembly panel (118).
cracked or broken glass, and melted conductor.
(d) Do not remove nuts (117) unless in-
(3) Replace fuse if defective.
spection reveals damage and replacement is neces-
sary.
(4) Install fuse and cap.
e.
Removal.
(2) Cleaning and Inspection.
(1) Disconnect wiring harness from back of fault
(a) Clean indicator light assembly with
locating indicator.
filtered compressed air and a soft bristle brush or
(2) Remove screws (1, figure 39.1) and lock-
wipe with a clean, lint-free cloth lightly moistened
washers (2) to remove fault locating indicator from
with an approved solvent.
Change 12