TO
35C2-3-442-2
P-8-627-34
TM-07464A-35
TM 5-6115-457-34
22.
1. Screw (3)
Lock washer (4)
23.
2. Lock washer (3)
Receptacle
24.
3. Cover
Gasket
4. Gasket
25.
P lug (2)
26.
Preformed packing (2)
5. Nut (2)
27.
6. Setscrew (2)
Filter assembly
28.
7. Screw (2)
Preformed packing
29.
Setscrew
8. Lock washer (2)
Bolt
30.
9. Core and armature assembly
10. Needle (2)
Lock washer
31.
11. Top orifice (2)
Link
32.
12. Preformed packing (4)
33.
Roll pin
13. Spacer (2)
34.
Retaining ring (2)
35.
14. Valve (2)
Washer (2)
15. Bottom orifice (2)
Preformed packing (2)
36.
37.
16. Screw (4)
Collar (2)
38.
17. Lock washer (4)
Quad-ring (2)
Piston
39.
18. Receptacle
40.
19. Gasket
Transducer assembly
20. Setscrew (2)
41.
Transducer body
21. Screw (4)
8-113. REPAIR.
WARNING
Avoid breathing fumes generated by
Cleaning Solvents are flammable and
tection is required.
moderately toxic to skin, eyes and
d. The filter assembly (27) may be re-
respiratory tract. Eye and skin
protection required. Good general
broken loose from the port body. Do not
ventilation is normally adequate.
attempt to solder up broken areas in the
a. Most repair work consists of polish-
screen mesh.
ing of parts. Use No. 320 to 500 fine grit
emery cloth for polishing all moving parts.
8-114. REASSEMBLY.
Clean after polishing with approved solvent
and dry thoroughly ,
governor actuator unit in the reverse order
b. Damaged threads can recleaned
of index numbers assigned. Pay particular
up using the proper size pipe tap to re-
attention to the following:
move burrs.
CAUTION
a. Coat piston (39) with clean hydraulic
Under no condition use a file on this
oil conforming to Military Specification
valve surface, its length is critical.
MIL-H-5606, prior to reassembly.
c. The valves (14) may be polished to
remove nicks and burrs or slight groove
b. If receptacle (23) had to be removed
marks on the bottom of the valve. If after
due to armature and coil assembly (9) re-
polishing the lower face the overall length
placement, reconnect coil leads to recept-
of the valve is less than 0.240 inch, replace
acle L1 and L2 coils as shown in figure
the valves (14).
8-27 as they are located when transducer