P-8-627-34 TO 35C2-3-442-2
TM-07464A-35
TM 5-6115-457-34
f. Check that actuator output shaft can
c. Connect hydraulic and electrical
connections.
move fuel inspection pump lever from full
throttle to closed throttle position accord-
d. Align actuator clevis hole with hole
ing to the scribe marks.
in linkage.
e. Loosen bolts securing pin bracket
g. If full operating range cannot be
and slide bracket forward. Pass pin through
reached, refer to linkage adjustment pro-
clevis and pin bracket. Then tighten bolts
cedure in the Operator and Organizational
and secure clevis to pin with cotter pin.
Maintenance Manual.
8-61
Change 8