TM 9-6115-668-13Table 2-4 Operator Preventive Maintenance Checks and Services-continued.ItemNo.IntervalLocationItem to Check/ServiceENGINE COMPARTMENT-continuedProcedurec.Drain condensation from twostep fuel filter.1. Hold small container underright filter cup (5) and left filtercup (8) of two step fuel filter (9).2. Remove drain plugs (6, 7) un-til mixture of fuel and condensa-tion water emerges from drainplug holes.3. When only fuel emerges,screw drain plugs (6, 7) back inone after another.4. Tighten drain plugs (6, 7).CAUTIONRemove collection container.5. Close flap (1).Not Fully MissionCapable if:Diesel engine runsroughly after startingbecause condensationwater has collected.2 - 2 4