TM 9-6115866-13
Item
No.
UNIT HOOD ASSEMBLY
1.
2.
Before
Before
Plates
Flaps
3.
Before
Ground straps
4.
Before
Cover for receptacles
5.
Before
Air leading ducts (cooling air
inlet for diesel engine)
6.
Before
Fuel Cap
Table 24 Operator Preventive Maintenance Checks and Services.
NOTE
If the equipment must be kept in continuous operation, check and service only those
items that can be checked and serviced without disturbing operation. Make the com-
plete checks and services when the equipment can be shut down.
Interval
Location
Item to Check/Service
Procedure
The fuel in this generator set
150 kW is highly explosive. Do
not smoke or use open flame
when performing mainte-
nance. Fire and explosion
could occur, resulting in 88
vere personal Injury or death.
Ensure key is in control cabinet
panel in the switch.
Check that all plates are firmly
attached and readable.
Check condition and operation
of twist grips, gas cylinders, and
door props.
Inspect ground straps and
ground strap connections for
looseness, corrosion, or dam-
age.
Check condition and attach-
ment of cover. Check for loose
or missing hardware.
Inspect air leading ducts for
looseness, damage, or dirt.
Inspect fuel cap, chain, hard-
ware, and strainer for looseness
or missing parts.
Not Fully Mission
Capable if:
Flaps cannot be fully
opened or main-
tained in the open
position.
Ground straps are
loose, damaged, or
corroded.
Cover is damaged or
loose.
Air leading ducts are
loose, damaged, or
dirty.
Fuel cap is missing.
Change 1
2-21