5.36 AIR FLAP PULLER MAGNET MAINTENANCE.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Tool Kit
Reference
(item 2, appendix B)
Generator Set 150 kW shut
Automotive Fuel and Electrical System Repair, Tool Kit
down,
(item 3, appendix B)
paragraph 2.5.2
WARNING
Disconnect the negative battery cable first and then the positive bat-
tery terminal cable. Failure to observe this warning could result in se-
vere personal injury or death.
C A U T I O N
Tag all cables prior to removal to ensure correct connection of the
cables during installation.
REMOVAL
1.
Open flap on unit hood assembly (1, figure 5-46).
2.
Remove screw (24) from plug connector X104 (25); remove plug connector (25).
3.
Loosen locknut (30) and unscrew tie rod (27) from fork member (31).
4.
Remove locknut (30) from tie rod (27) and remove helical spring (29).
5.
Remove four screws (40), four serrated lock washers (39), and four washers (38) from bracket (28).
6.
Remove air flap puller magnet (26) from bracket (28).
INSTALLATION
1.
Place air flap puller magnet (26) on bracket (28).
2.
Install four screws (40), four serrated lock washers (39), and four washers (38) on bracket (28).
Tighten screws (40).
3.
Slide helical spring (29) an locknut (30) on tie rod (27).
4.
Screw tie rod (27) into fork member (31) and tighten locknut (30).
5.
Install plug connector X104 (25) using screw (24). Tighten screw (24).
C A U T I O N
Check that air flap closes and linkage moves freely.
6. Close flap (2).
5-187