TM 9-6115-668-135.34 OVERTEMPERATURE SWITCH MAINTENANCE.This task covers:a. Removalb. InstallationINITIAL SETUPToolsEquipmentConditionsGeneral Mechanic’s Tool KitReference(item 2, appendix B)Generator Set 150 kW shutAutomotive Fuel and Electrical System Repair, Tool Kitdown,(item 3, appendix B)paragraph 2.5.2WARNINGDisconnect the negative battery cable first and then the positive bat-tery terminal cable. Failure to observe this warning could result in se-vere personal injury or death.C A U T I O NTag all cables prior to removal to ensure correct connection of thecables during installation.REMOVAL1.Open flap (2, figure 5-44) on unit hood assembly (1).C A U T I O NDo not pull flat connectors off cables.INSTALLATION2.Remove both flat connectors X110 (18) on overtemperature switch S110 (17).3.Remove overtemperature switch S110 (17) from heating unit (10).1.Screw overtemperature switch S110 (17) into heating unit (10).N O T EPass cables under cable bridges.2.Connect both flat connectors X110 (18) on overtemperature switch S110 (17).3. Close flap (2).5-182