TM 9-6115-668-13
b. Pull relay K19 (7) out of relay socket (16).
5.
Remove relay socket (16) with contact bushings:
a. Remove nut (9), serrated lock washer (10), and washer (11) from standoff (8).
b. Remove relay board (15) with relay K20 (6) from standoff (8).
c. Remove nut (12), serrated lock washer (13) and washer (14) from threaded element (17).
d. Remove threaded element (17) and relay socket (16) from relay board (15).
C A U T I O N
Use only removal tool to push out contact bushings.
6. Remove contact bushings:
7.
Insert removal tool from the front into contact bushing and push contact bushing with cable out of
relay socket (16).
C A U T I O N
Use only installation tool to Insert contact bushings.
1.
2.
Insert relay socket (16) into relay board (15).
3.
Install two washers (11), two serrated lock washers (10), and two nuts (9) on two standoffs (8).
4.
Insert relay K19 (7) into relay socket (16).
5.
Install two screws (20)) two serrated lock washers (19), and two washers (18).
6.
Install digital isochronous load sharing module N4 (36) as instructed in paragraph 5.11.
7.
Stow prop (5) and close front panel (4).
8.
Close flap (2).
Slide installation tool over contact bushing and push contact bushing with cable into relay socket
(16).
5-116