TM 9-6115-668-134.64 TRUE POWER MEASURING TRANSFORMER P4A MAINTENANCE.This task covers:a. Removalb. InstallationToolsEquipmentConditionsGeneral Mechanic’s Tool Kit(item 2, appendix B)Automotive Fuel and Electrical System Repair, Tool Kit(item 3, appendix B)Materials/PartsReferenceGenerator Set 150 kW shutdown,paragraph 2.5.2Cable ties(item 10, appendix E)Disconnect the negative battery cable first and then the positive bat-tery terminal cables. Failureto observe this warning could result in se-vere personal injury or death.Tag ail cables prior to removal to ensure correct connection of the cablesduring installation.1.Open flap (2, figure 4-54) on unit hood assembly (1).2.Open front panel (4) on control cabinet assembly (3) and secure with prop (5).3.Open cable conduit (47) and cable conduit (60).4.Record labeling and position of cables and disconnect cables (51, 52) from terminals (50, 53) oftrue power measuring transformer P4A (15).5.Record labeling and position of cables and disconnect cables (55, 56) from terminals (54, 57) oftrue power measuring transformer P4A (15).6.Use a screwdriver to push unlocking element (16) on true power measuring transformer P4A (15) indirection of arrow, tilt true power measuring transformer P4A (15) upward and remove from mount-ing bar (14).4 - 1 5 5