TM 9-6115-668-13
4.65 RESISTOR R100 TO R102 MAINTENANCE.
This task covers:
a. Removal
b. Installation
Tools
Equipment Conditions
General Mechanics Tool Kit
Reference
(item 2, appendix B)
Generator Set 150 kW shut
Automotive Fuel and Electrical System Repair, Tool Kit
down,
(item 3, appendix B)
paragraph 2.5.2
Materials/Parts
Solder (item 12, appendix E)
Thermoconductive paste (item 13, appendix E)
Cable ties (item 10, appendix E)
Disconnect the negative battery cable first and then the positive bat-
tery terminal cables. Failure to observe this warning could result in se-
vere personal injury or death.
Tag all cables prior to removal to ensure correct connection of the cables
during installation.
1.
Open flap (2, figure 4-55) on unit hood assembly (1).
2.
Open front panel (4) on control cabinet assembly (3) and secure with prop (5).
3.
Remove speed governor assembly N1 (44) as instructed in paragraph 5.13.
4.
Remove resistor R 100 (55):
Removal procedure for resistor R101 and R102 is the same as for resis-
tor R100, described below.
a. Remove mounting plate (58) with resistors R100 (55) to R102 (57) from speed governor assem-
bly N1 (43).
b. Unsolder cable (52) from resistor R100 (55).
c. Remove two screws (49), two serrated lock washers (50), and two washers (51).
d. Remove resistor R100 (55) from mounting plate (58).
4 - 1 5 8