TM 9-6115-662-13&PItemNo.373839404142Table 2-2. Operator Preventive Maintenance Checks and Servicesfor AN/MJQ-40, PU-803, and PU-804 (continued)LocationNot Fully MissionIntervalItem to Check/ServiceProcedureCapable if:WARNINGExercise extreme caution when performing “DURING” checks inside enginecompartment. Avoid contact with moving or hot engine parts. Failure to observethis warning can result in severe personal injury or death.DuringDuringDuringDuringDuringGENERATORSETENGINE ASSEMBLYCheck for loose, damaged ormissing parts.FUEL SYSTEMInspect for leaks.LUBRICATION SYSTEMa. Inspect for leaks.b. Check oil level on dipstick, bothsides.COOLING FANListen for unusual noise in fanarea.GROUND ROD CABLE AND Inspect ground rod and cable forCONNECTIONSloose connections, breaks, damage,and corrosion.WARNINGAny fuel leaks.Class III leaks.Oil level below ADDlevel.Cable is missing ordamaged.DuringHigh voltage is produced when this generator set is operating. Improperoperation could result in injury or death.CONTROLS ANDObserve the following indicatorsINDICATORSand ensure they are functioning.Coolant temp, 170-200°F (77-93° c)Oil pressure, 25-60psi (172-414kPA)2-25