TM 9-6115-662-13&PItemNo.43444546474849IntervalAfterAfterAfterTable 2-2. Operator Preventive Maintenance Checks and Servicesfor AN/MJQ-40, PU-803, and PU-804 (continued)LocationItem to Check/ServiceGENERATOR SET -ContinuedHOUSINGIDENTIFICATION PLATESSKID BASENot Fully MissionProcedureCapable if:a.b.Check doors, panels, hinges,and latches for damage, loose,or corroded items.Inspect air intake and exhaustgrills for debris.Check to be sure identificationplates are secure.Inspect skid base for cracks andcorrosion.WARNINGCannot secure doors.Intake and exhaustgrills plugged.ISkid base cracked orIshows signs ofstructural damage.AfterAfterAfterAfterDO NOT smoke or use open flame near this generator set. The fuels used in itare highly explosive. Flames and explosion can occur, resulting in severepersonal injury or death.ENGINE ASSEMBLYFUEL SYSTEMFUEL FILTER/WATERSEPARATORLUBRICATION SYSTEMCheck for loose, damaged, ormissing hardware.Inspect fuel system for leaks,damaged, loose, or missinghardware.a.b.a.b.c.Inspect fuel filter/waterseparator for leaks, cracks,damage, proper mounting, ormissing parts.Drain water from fuelfilter/water separator.Inspect lubrication system forleaks, damaged, loose, ormissing parts.Check oil level.Check engine oil forcontamination.Any fuel leaks,damaged, loose, ormissing parts.Any fuel leaks.Class III leaks,damaged, loose, ormissing parts.Oil level is belowADD level.Engine oil showscontamination.2-26