TM 9-6115-660-13&PTable 1-5. Tabulated Data for Power Plants/Power Units - continuedData PU-798A PU-799AOverall length, inches (cm)135.0 (342.9)135.0 (342.9)Overall width, inches (cm)86.0 (218.4)86.0 (218.4)Overall height, inches (cm)66.3 (168.4)66.3 (168.4)Operational weight, pounds (kg)Shipping weight, pounds (kg)2480 (1124.9)2510 (1138.5)Section III. PRINCIPLES OF OPERATION1-13. FUNCTIONAL DESCRIPTION.1-13.1. PowerPlantFunctionalDescription. The Power Plants are mobile. The power source for the AN/MJQ-37power plant is two DOD Model MEP-803A, 60 Hz, Tactical Quiet, 10 kW Generator Sets. The power source for theAN/MJQ-38 power plant is two DOD Model MEP-813A, 400 Hz, Tactical Quiet 10 kW Generator Sets. Generators foreach power plant are mounted on a single modified M103A3 2-wheel 1 1/2 ton trailer. Each generator set consists of aliquid-cooled diesel engine, brushless generator, excitation system, speed governing system, fuel system, 24-volt directcu-rent starting system, control system, and malfunction protection system. The generator set has a voltage reconnectionswitch that allows either of three output configurations: 120-volt, single phase, 2-wire; 120/240-volt, single phase, 3-wire; or120/208-volt, three phase, 4-wire. Electrical power to the supported system or equipment is supplied through a switch boxassembly. The switch box assembly is connected between the two generator sets by power cables. The switch boxenables transfer of the load from one generator set to the other without interruption of power. The system or equipmentload cable may be connected to the switch box by either of two arrangements. One way is to connect a load cable to theswitch box output connector. The other way is to connect a load cable to the switch box load terminals.1-13.2 PowerUnitFunctionalDescription.The Power Units are mobile. PU-798 and PU-798A each use one DODModel MEP-803A, Tactical Quiet, 60 Hz, 10 kW Generator Set. PU-799 and PU-799A each use one DOD Model MEP-813A, Tactical Quiet, 400 Hz, 10 kW Generator Set. The generator set for each power unit is mounted on a modifiedM116A3, 2-wheel, 1-ton trailer (PU-798 and PU-799) or a modified high mobility, 2-wheel trailer (PU-798A and PU-799A).The generator sets consist of a liquid-cooled diesel engine, brushless generator, excitation system, speed governingsystem, fuel system, 24-volt direct current starting system, control system, and malfunction protection system. Thegenerator set has a voltage reconnection switch that allows either of three output configuration,: 120-volt, single phase, 2-wire; 120/240-volt, single phase, 3-wire; or 120/208-volt, three phase, 4-wile. System or equipment load cables are to beconnected to the load terminals on the generator set output panel.1-14. RELATED TECHNICAL MANUALS.Refer to Appendix A for related technical manuals and lubrication orders.Change 2 1-9/(1-10 Blank)
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business