TM 9-6115-659-13&P
4-14 INDICATOR LIGHT ASSEMBLY MAINTENANCE.
This task covers: a. Test
c. Repair
b. Removal
d. Installation
Tools
Tool Kit, General Mechanics
(item 1, appendix B)
Soldering Gun GT7A-3
(item 2, appendix B)
Hand Operated Terminal Crimping Tool
(item 2, appendix B)
Materials/Parts
Insulation Sleeving, Heat Shrinkable
Terminal, Lug, Crimp, 22-18 AWG, 0.138 Stud
Solder
Equipment Conditions
Reference
Both generator sets shut down,
paragraph 2-5.3.3.
Switch box cover open.
1.
2.
Measure for continuity between terminals (5, figure 4-14). If continuity exists, replace lamp housing.
Measure for continuity of indicator light assembly leads (7) between terminals (5 and 8) in accordance
w i t h t a b l e 4 - 2 .
Figure 4-14. lndicator Light Assembly.
4-29