TM 9-6115-604-34NAVFAC P-8-633-34Figure 2-11. Generator G1, Checking Exciter Air Gap(41)Install roof panels 5 and 6 (see Figure 2-2) over generator in accordance with paragraph 4-17 of Operatorand Organizational Maintenance Manual.(42)Install ac and dc conduit above generator in accordance with paragraph 4-35 of the Operator andOrganizational Maintenance Manual.(43)Install roof panels 1 through 4 (see Figure 2-2) above the engine in accordance with paragraph 4-17 of theOperator and Organizational Maintenance Manual and figure 4-12.(44)Install the exhaust system components that connect the mufflers to the turbocharger outlets in accordancewith paragraph 3-15 of the Operator and Organizational Maintenance Manual.(45)Install the mufflers in accordance with paragraph 4-86 of the Operator and Organizational MaintenanceManual.(46)Install radiator shutter and radiator in accordance with paragraph 4-55 of the Operator and OrganizationalMaintenance Manual.(47)Install fan and pulley guards in accordance with paragraph 4-59 of the Operator and OrganizationalMaintenance Manual.(48)Install the ac and dc lights and conduits above the engine in accordance with paragraph 4-35 of theOperator and Organizational Maintenance Manual.(49)Reconnect the engine wiring harness in accordance with paragraph 4-22 of the Operator andOrganizational Maintenance Manual.2-37