ARMY TM 9-61150412
NAVY NAVFAC P-8-633-12
Table 1-1. System Capacities and Detailed Data on Components (Continued)
2.
DC ELECTRIC AND CONTROL SYSTEM (CONTINUED)
Manufacturer:
Synchro Start Products
Part Number:
60 Hz, Dash No-5:
SA-2485-3D08
FSCM:
78388
MAINTENANCE LOCKOUT Switch S100
Drawing Number:
80-7859
Electrical Characteristics:
240 V ac, 225 amperes, non-automatic trip
10, 000 amperes interrupting capacity
UL listed conforming to Federal
Specification WC-375B
Number of Poles:
3
Operating Temperature:
-25 to +125°F (-31 to 51°C)
Storage Temperature:
-5 to +155°F (-53 to 68 C)
Humidity Conditions:
To 100%
Manufacturer:
General Electric Company
Part Number:
TQD32Y225LL
FSCM:
28432
24 VDC CONTROL POWER Circuit
Breaker CB1
Drawing Number:
80-7637
Voltage:
:
120 V ac
Drawing Number:
80-7637-01 80-7637-02
Trip Current:
15 20
Part Number:
EB1015L EB1020L
Poles:
One
Specifications:
Per Federal Specification WC-375
Operating Temperature:
-25 to +125°F (-31 to 51C)
Storage Temperature:
-65 to +155°F (-53 to 68°C)
Humidity Conditions:
To 100%
Manufacturer:
Westinghouse Electric Company
Part Number:
Model-01:
EB1015L
Model-02:
EB1020L
FSCM:
89946
Fuel Level Switches FL1 and FL2
Drawing Number:
80-7533
Electrical Rating:
0.5 ampere resistive or Inductive
(UP-0.026) at 6 to 32 V dc or
10 watts at 100 to 220 V ac
Operating Pressure:
0 to 150 psi (0 to 1034 kPa)
Operating Medium:
Diesel fuel
-0.849 specific gravity
JP-4
-0 775 specific gravity
Gasoline
-0 742 specific gravity
Operating Temperature:
-25 to +125°F (-31 to 51°C)
Storage Temperature:
-65 to +155 F (-53 to 68 C)
Humidity Conditions:
To 100%
Manufacturer:
The Air Flow Instrument Company
Part Number:
8048-100-2
FSCM:
06102
1-21