ARMY TM 9-6115-604-12
NAVY NAVFAC P-633-12
Table 1-1. System Capacities and Detailed Data on Components (Continued)
3. AC ELECTRICAL POWER GENERATION AND CONTROL SYSTEM (CONTINUED)
Power Cable
Drawing Number:
80-7901
Material:
Type W/3 conductor, round/600/2000 V
Conductor Size:
No 4
Strand
259
Nominal Insulation Thickness:
0.060 Inch (1.524 mm)
Nominal Jacket Thickness:
0 141 Inch (3.581 mm)
Nominal Outer Diameter:
1 17 inch (29 72 mm)
Ampacity:
104
Operating Temperature:
-25 to +125°F (-31 to 51°C)
Storage Temperature:
-65 to +155°F (-53 to 68°C)
Humidity Conditions:
To 100%
Manufacturer:
E. J. Stephens Inc.
Part Number:
PC13030, Type W/3
FSCM:
None
4. FUEL SYSTEM
Transfer Pump Assembly B102
Drawing Number:
80-7527
Design Rating:
9.5 gpm (4.28 Umin) at 1140 rpm
Materials:
Gray iron housing and steel gears
Bearings:
Replaceable sleeve type
Seal:
Mechanical shaft type
Lubrication:
Self-lubricating (using fluid being pumped)
Rotation:
Clockwise facing pump shaft
Suction Lift:
15 Inch Hg minimum
Drive:
Direct connected
Key:
0.187 square by 0.75 long steel
furnished loose
Operating Temperature:
-25 to +125°F (-31 to 51 C)
Storage Temperature:
-65 to +155°F (-53 to 68°C)
Humidity Conditions:
To 100%
Manufacturer:
Brown & Sharpe Company
Part Number:
713-30-7
FSCM:
09058
Electric Motor
Drawing Number:
80-7684
Rating:
NEMA frame 56, fully enclosed cap.
start; fan-cooled - counterclockwise
rotation (facing shaft)
115/208 V ac, single phase, 50/60 Hz;
8/4-4 amperes full load,
0.5 horsepower, 1140 rpm
Operating Temperature:
-25 to +125°F (-31 to 51°C)
Storage Temperature:
-65 to +155°F (-53 to 68°C)
Humidity Conditions:
To 100%
Manufacturer:
Baldor Electric Company
Part Number:
L3505
FSCM:
05472
1-26