ARMY TM 9-6115-604-12NAVY NAVFAC P-8-633-12bd. COOLANTTFMPGageM3(10.Figure2-1).Inspect for cleanliness and signs of damage. Check for secure panelmounting and for chipped, cracked, or loose cover glass and broken Indicator.be. LUBE OIL TFMP Gage M2 (11. Figure 2-1) Inspect for cleanliness and signs of damage Check for secure panelmounting and for chipped, cracked, or loose cover glass and broken indicator.bf. TIME TOTALIZ1NG Meter M5 (12. Figure 2-1) Inspect for cleanliness and signs of damage Check for secure panelmounting and for chipped, cracked, or loose cover glass and broken Indicator.bg. PANELLIGHTSSwitchS1(13.Figure2-1) Inspect for cleanliness and signs of damage. Check security ofmounting and for operation In both positions.bh. START AID Switch S 10 (14. Figure 2-1). Inspect switch for cleanliness and secure mounting. Toggle switch on andoff to verify proper operation.bi.MASTER(START/STOP/RUN)SWITCHS9(16.Figure2-11Inspect for cleanliness and signs of damage. Checksecurity of mounting and for operation In START, RUN, and STOP positions.bl.UtilityStationPowerTransformerT103(Figure3-29).Utility station power transformer T103 Is located In the lowerrear section of engine control cabinet C. Inspect transformer for cleanliness and damage Check mounting andwiring connections for security Check for burned Insulation and telltale odors of overheating. Refer any evidence ofoverheating or damage to the next higher level of maintenance.Do not touch fuse during inspection or attempt to remove and replacefuse by hand. Verify that the generator set is completely shut off priorto servicing the fuse. Use a grounding stick on both terminal ends ofthe fuse holder to discharge any residual voltages present on linesand components. Use properly insulated tools and equipment toremove and replace the fuse. Failure to heed this warning may resultin death or serious injury.bk.SetStationPowerTransformerT101(Figure2-12). Set station power transformer T101 Is located In the lowerfront section of engine control cabinet C Inspect transformer for cleanliness and obvious damage Checkmounting and wiring connections for security Check for burned insulation and telltale odors of overheating.bl.StripHeaterH105.See(Figure3-29)Strip heater H105 Is mounted on the right cabinet panel, rear Interiorsection of engine control cabinet C Inspect heater for secure mounting and wiring connections. Check forsigns of scorching, burned insulation, and damage.bm.HumidistatS107(1.Figure2-12)Humidistat S107 Is mounted on the Interior right side panel of engine control.cabinet C Check humidistat for secure mounting and wiring connections, and damage.To avoid injury to personnel, no electrical component will be workedon while energized. Ensure equipment is "tagged out" in accordancewith Chapter 1, Section III, of this manual and equipment is NOTenergized. Residual voltage is present at the generator leads with theregulator turned off, reaching SEVERAL HUNDRED VOLTS on thegenerator set. Proper insulation and isolation of metering equipmentmust be observed when testing this generator. USE PROPER TESTEQUIPMENT TO CHECK FOR VOLTAGE before proceeding with work.3-75
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business