ARMY TM 9-6115-464-12
AIR FORCE TO 35C2-3-445-1
NAVY NAVFAC P-8-624-12
Item
No.
1
2
3
4
5
6
7
8
9
10
4-6
NOTE
For generator sets in continuous operation, check and service only those items that
can be checked and serviced without disturbing operation. Perform a complete
PMCS when equipment can be shutdown. Deficienaes discovered during operation
shall be noted for future correction. Stop the operation immediately if a deficiency is
noted which could damage the equipment. Report all deficienaes and corrective ac-
tions on paper forms. Army, refer to DA Pamphlet 738-750. Air Force, refer to applica-
ble inspection manuals and work card sets in the TO 35C2-3-1-426 series for period-
ic requirements and Table 4-1 for detailed procedures. Operator PMCS apply to
Navy users in this manual.
. . .
Table 4-1. Unit Preventive Maintenance Checks and Services
Interval
Hours
Hours
Hours
Hours
Hours
Hours
Hours
Hours
Hours
Weekly
Location
Item to
Check\
Service
Fuel Pump
Filters
Fuel Filters
Hydraulic Sump
Hydraulic Filter
Hydraulic Actua-
tor Screen
Breather and
Breather Tube
Engine Oil
Oil Filters
Air Cleaner
Fluid Levels
Hydraulic sump
(electro-hydraulic
governor
equipped precise
sets only
Procedure
Change every 100 hours (para 4-29,
Figure 4-15).
Replace filter elements every 100 hours (para
4-29, 4-31, and Figure 4-15 and
Figure 4-16).
NOTE
Items 9, 10 and 11 apply to electro-hy-
draulic governor equipped precise sets
only.
Drain and refill (para 4-47). (Refer to LO).
Replace filter (para 4-47). (Refer to LO).
Clean filter (para 4-48). (Refer to LO).
Inspect for damage. Clean breather and breath-
er tube at oil change interval as directed by
Army Oil Analysis Program (para 4-54).
As directed by Army Oil Analysis Program.
As directed by Army Oil Analysis Program.
This unit is equipped with an air filter condition
indicator light that will indicate when filter ele-
ment needs cleaning. Clean element when
necessary as indicated by light (para 3-20).
Check fluid levels
Check fluid level. Add fluid as required.
Not
Mission
Capable If:
Air cleaner
missing.