TM5-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-14&P/16-4.REPLACE FAULTY COMPONENT OF SPECIAL RELAY ASSEMBLY (cont)f. Replace faulty K3 relay:(1) Tag and remove wires fromfaulty K3 relay (11).(2) Remove two screws (12) andnuts (13) and remove faultyK3 relay (11).(3) Install new K3 relay (11)and secure with two screws(12) and nuts (13).(4) Attach wires to new K3relay (11).g.Replace faulty special currenttransformer:(1) Tag and remove wires fromfaulty special currenttransformer (14).(2) Remove two screws (15)and nuts (16) and removefaulty special currenttransformer (14).(3) Install new special cur-rent transformer (14) andsecure with two screws(15) and nuts (16).(4) Attach wires to newspecial current trans-former (14).h.Replace faulty diode assembly:(1) Remove two screws (17)from terminal board (18)and remove faulty diodeassembly (19).(2) Secure new diode assembly(19) on terminal board(18) with two screws (17).i.Replace R31 fixed resistor:(1) Tag and remove wires fromfaulty R31 fixed resistor.6-6