TM5-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-14&P/16-4.REPLACE FAULTY COMPONENT OF SPECIAL RELAY ASSEMBLY (cont)c.Replace faulty wiring harness:(1) Remove all wires of faultywiring harness (6). (Notshown).(2) Attach new wiring harness(6) using wiring diagramfigure 5-1.d.Replace faulty dc relayassembly:(1) Tag and remove wires fromfaulty dc relay assembly(7).(2) Remove four screws (8) andremove faulty dc relayassembly (7).(3) Install new dc relay assem-bly (7) and secure withfour screws (8).(4) Attach wires to new dcrelay assembly (7).e.Replace faulty instrument shunt:(1) Tag and remove wires fromfaulty instrument shunt(9).(2) Remove two screws (10) andremove faulty instrumentshunt (9).(3) Install new instrumentshunt (9) and secure withtwo screws (10).(4) Attach wires to new in-strument shunt (9).6-5