5-58
TM5-6115-634-14&P
NAVFAC P-8-647-14&P
T0-35C2-3-445-14
TM-6115-14&P/1
5-29. TEST AND REPAIR REMOTE CONTROL UNIT (cont)
g.
Inspect all connections for
compliance with FO-2 wiring
diagram.
Then remove tags.
h.
Replace wiring harness as
follows:
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Tag and mark wires con-
nected to switches, con-
trols and indicators.
Remove ring nut (3) from
J29D connector (4). Remove
wiring harness.
Get a new wiring harness
to tag and mark wires to
tag and mark wires to
exact match with the old
wiring harness.
Connect wires to controls,
switches, and indicators
per tags.
Ensure all con-
nections are in accordance
with the schematic diagram
(FO-2).
Solder connections to in-
dicators in accordance
with MIL-STD-454.
Secure wiring harness with
wire straps.
Install connector J29D (4)
to with ring nut (3).
Install control panel (2)
to housing and secure with
six screws (1).
Test the remote control
unit by operating the
generator set in the
remote mode.