5-56TM5-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-14&P/15-29. TEST AND REPAIR REMOTE CONTROL UNIT (cont)NOTEAll switches are removed in thesame manner.The BATTLESHORTON/OFF switch has one additionalpart which will be identified inthe following steps.(1) Tag and disconnect elec-trical leads from switchterminals.(2) Remove nut (5), lockwasher(6), locking ring (7),switch guard (8) forBATTLESHORT ON/OFF switchonly, switch (9) and nut(10). Retain mountinghardware.c. Install ENGINE START/STOP, CON-TACTOR CLOSE/OPEN and BATTLE-SHORT ON/OFF switches.NOTEAll switches are installed in thesame manner.The BATTLESHORT ON/OFF switch has one additional partwhich will be identified in thefollowing steps.(1) Obtain replacement switch(9). Install nut (10) onswitch (9), switch guard(8) BATTLESHORT ON/OFFswitch only, locking ring(7) , lockwasher (6) andnut (5).(2) Reconnect tagged electri-cal leads to switch ter-minals.d.Replace FREQ ADJUST rheostatsas follows:(1) Tag and disconnect wireleads from R32 terminals.(2) Remove knob (11) , nut andwasher assembly (12), andrheostat (13) from panel.