TM5-6115-634-14&PNAVFAC P-8-647-14&PT0-35C2-3-445-14TM-6115-14&P/1MAINTENANCE REMOTE CONTROL UNIT5-29.TEST AND REPAIR REMOTE CONTROL UNITThis task covers: a. Testb. RepairINITIAL SETUPToolsGeneral Mechanic’s Tool Kit5180-00-177-7033Multimeter6625-01-139-2512Solder/Desolder Kit3439-00-460-7198Materials/PartsRemote Control Unit97403-13228E1869TEST1.TEST INDICATOR LIGHT ASSEMBLIES.a.Remove LOW FUEL, ENG RUNNINGand CONTACTOR CLOSED lamps.Use an ohmmeter to test thelamps for burned out filaments.Replace turned out lamps.b.Remove SYN LIGHT lamps. Usean ohmmeter to test the lampsfor burned out filaments.Replace burned out lamps.2.TEST SWITCHES, CONTROLS AND WIRINGHARNESS.NOTERefer to FO-2 for the followingprocedures.a.Connect ohmmeter leads acrossJ29D pins A and B. Toggle S18to RUN position. Meter indi-cation should be O ohms.b.Connect ohmmeter leads acrossJ29D, pins A and C.Toggleand hold S18 to START position.Meter indication should be O ohms.5-53