TM 5-6115-593-12TO 35C2-3-463-1TABLE 3-3. OPERATOR/CREW TROUBLESHOOTINGMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION2.ENGINE CRANKS BUT WILL NOT START - ContinuedStep 4.Check LOW FUEL LEVEL indicator lamp on GeneratorControl Panel.If lit, temporarily set BATTLE SHORT switch to ON. Ifengine starts set MASTER SWITCH to STOP and check fueloil levels in auxiliary tanks. Set FUEL PUMP switch to AUTOif not already in this position. If LOW FUEL LEVEL indicatorlamp is not lit refer malfunction to next higher level ofmaintenance.3.ENGINE SHUTS DOWN SOON AFTER STARTING.Check engine fault indicators.Check for low fuel oil level in day tank.Add fuel oil as required.4.ENGINE SHUTS DOWN AND WILL NOT RESTART.Step 1.Check ENG FAULT indicator lamps on GeneratorControl Panel.If any one of them is lit refer to appropriatesubsequent step.Step 2.If HI COOL TEMP indicator lamp is lit, check coolantlevel at radiator sight glass.If low add coolant (as required by weatherconditions).WARNINGRemove radiator cap slowly to permit pressure to escape prior to removal of cap.If coolant level normal, refer to next higher level of maintenance.Step 3.If HI LUB TEMP indicator lamp is lit, check lube oil level using oillevel sight gauge.Add lube oil as required.Step 4.If LOW OIL PRESS indicator lamp is lit, check lube oil level using oillevel sight gauge.Add lube oil as required.3-7