TM 5-6115-593-12TO 35C2-3-463-1TABLE 3-3. OPERATOR/CREW TROUBLESHOOTINGMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION4.ENGINE SHUTS DOWN AND WILL NOT RESTART-ContinuedStep 5.If LOW FUEL LEVEL indicator lamp is lit, check level of fuel inauxiliary tank.If empty, refill as required.Step 6.Check OVERSPEED indicator lamp.If lit, refer to next higher level of maintenance.5.ENGINE RUNS ERRATICALLY OR MISFIRES.Step 1.Check engine fuel oil for contamination.If contaminated, drain fuel system and fillwith proper fuel.Step 2.Inspect air cleaner assembly for excessive dirt.If excessive dirt is present, refer to nexthigher maintenance for replacement.6. ENGINE EXHAUST EXCESSIVELY BLACK.Step 1.Inspect air cleaner assembly for excessive dirt.If excessive dirt is present, refer to nexthigher maintenance for replacement.Step 2.Check KW meter on Generator Control Panel.Reduce load to rated level. If KW meterreading is within rated level, refer to nexthigher level of maintenance.7.ENGINE EXHAUST WHITE OR BLUE.Step 1.Check for improper fuel.Drain fuel system and fill with proper fuel.Step 2.Check for excessive lube oil using dipstick orsight gauge.Drain crankcase until proper level isindicated.3-8