Table 3-1. Consumable Operating and Maintenance Supplies - Continued
COMPONENT
APPLICATION
NATIONAL STOCK
NUMBER
DESCRIPTION
QTY
REQUIRED
FOR INITIAL
OPERATION
QTY
REQUIRED
8 HOURS
OPERATION
NOTES
Crankcase
9150-00-265-9435(1)
Grade,
(6)
(9)
(5) One tank, if
(Cont'd)
OE/HDO 30
required for cold
MIL-L-2140
weather starting
9150-00-265-9428(1)
Grade,
(6)
(9)
OE/HDO 10
MIL-L-2104
9150-00-242-7603(1)
55 Gal Drum
(209 1)
9150-00-265-9436(1)
Grade,
(6)
(9)
(6) Crankcase
OE/HDO 30
Capacity 19 gal.
MIL-L-2104
(68 1)
9150-00-191-2972(1)
Grade,
(6)
(9)
(7) Cooling System
OE/HDO 10
Capacity 52 gal.
MIL-L-2104
(197 1)
(8) See LO for
lube points
9150-00-242-7604(1)
Grade OES
(5)
(9)
(9) See LO for
MIL-L-10295
grade application
and replenishment
intervals.
Electric
9150-00-242-7604(1)
Grade OES
(10)
(9)
(10) Electric
Hydraulic
MIL-L-10295
Hydraulic Actuator
Actuator
Sump Capacity
1 gal. (3.7 1)
Parts,
6950-00-281-1985(2)
Solvent
Cleaning
(1 gal
.
3.8 1) Can
FED-P-D-680
Batteries
6810-00-249-9354
Electrolyte
(10)
(10) Requires
3 1/2 gal. fill
batteries
Radiator
6850-00-243-1992(2)
Coolant
(7)
(7)
Anti-Freeze
Inhibited
Glycol
6850-00-174-1806
Anti-Freeze
(7)
(7)
Compound
Artic