TM 5-6115-584-12
NAVFAC P-8-622-12
TO-35C2-3-456-1
TM-05682C-12
Figure 4-34. Removing Control Cubicle Support Assembly
(3) Battery Charging Indicator (M1). Tag and
disconnect lead to indicator. Remove two lockwashers
and nuts and retainer holding meter in place and
remove indicator.
(4) DC Control Circuit Breaker (CB2). Discon-
nect two leads to breaker. Remove two screws
attaching breaker to control panel and remove breaker.
(5) Master Switch (S1). Disconnect battery. Tag
and disconnect seven leads to master switch. Re-
move switch knob by loosening two setscrews. Remove
nut attaching switch to control panel and remove
switch.
(6) Panel Light Switch (S2). Tag and disconnect
two leads to switch. Remove nut attaching switch
to control panel and remove switch.
(7) Ammeter - Voltmeter Transfer Switch (S8). Tag
and disconnect sixteen leads to range selector switch.
Remove switch knob by loosening two setscrews.
Remove nut attaching switch to control panel and
remove switch. Install new switch as given above.
(8) Voltage Adjust Rheostat (R1). Tag and dis-
connect two leads to rheostat. Remove rheostat knob
by loosening two allen setscrews. Remove nut and
washer attaching rheostat to panel and remove rheostat
(9).
(9) Transformer (T1). Tag and disconnect five
leads to transformer. Remove four screws and
lockwashers attaching transformer to control cubicle
and remove transformer.
(10) Transformer (T2). Tag and disconnect four
leads to transformer. Remove two screws and lock-
washers attaching transformer to cubicle and remove
transformer.
Change 3
4-43