Figure 4-33.1.d. Disassembly.(1) Panel Light Assemblies (DS1) and (DS2) (seefigure 4-33). Tag and detach two leads to each panellight assembly (DS1) and (DS2). Remove nut and lock-washer securing light assembly to control panel andremove light assembly.(2) Hour Meter (M2). Tag and disconnect twoleads to hour meter. Remove three screws, lock-washers, and nuts attaching hour meter to controlpanel and remove meter.TM 5-6115-584-12NAVFAC P-8-622-12TO-35C2-3-456-1TM-05682C-12(3) Relay Assembly (A1). Inspect relay assembly(5) for physical damage.Check that electrical con-nections to assembly are clean and tight. Check thatassembly is securely attached to control cubicle.(4) Relay (K1). Inspect relay (6) for physicaldamage and continuity (see figure 4-33.1). Remove relayfrom socket and inspect for bent or missing pins. Checkthat relay is secured to socket with two screws.4-42.2Change 5