P-9-TM-457-35
T.O. 35C2-3-442-2
TM-07464A-35 TM 5-6115-457-34
Figure 8-38. Utility governor droop setting
2. Install new gaskets (57 and 59,
d. UTILITY GOVERNOR, LINKAGE AND OVER-
SPEED SHUTDOWN DEVICE. Refer to figures
8-31 and 8-31A and install utility gov-
e r n o r , linkage, oil lines and overspeed
3. Install utility governor (56) on
shutdown device in the reverse order of
the four mounting studs of the governor
index numbers assigned. Pay particular
drive housing. Governor drive coupling
a t t e n t i o n to the following:
Insert governor drive coupling
utility governor drive shaft. Do not force.
If coupling and spline do not engage, pull
housing and engage spline.
Change 2
8-85