P-9-TM-457-35
T.O. 35C2-3-442-2
TM-07464A-35
TM 5-6115-457-34
Table 2-3. Troubleshooting (Continued)
PROBABLE CAUSE
MALFUNCTION
CORRECTIVE ACTION
a. Adjust or replace rheostat
a. Defective or improper-
37. During parallel oper-
ly adjusted real load
6-193).
sharing rheostat R28.
do not share real
load (KW) equally
b. Align system
(precise generator
b. Precise governor
system not properly
sets).
aligned.
c. Defective current
c. Test and replace if defec-
CT2, or CT3.
d. Defective tactical relay
box.
regulator.
a. Adjust or repair governor
a. Defective or improper-
38. During parallel oper-
ly adjusted utility
do not share real
governor.
load (KW) equally
(utility generator
b. Repair linkage
b. Defective governor
linkage.
sets).
39. Engine misses or
a. Incorrect fuel injection
a. Reset timing
runs erratically.
timing.
b. Sticking valves.
b. Free valves
c. Broken rocker arm
c. Replace rocker arm
assembly.
d. Cracked cylinder liner.
d. Replace liner
2-44
Change 3