DANGEROUS VOLTAGE EXISTS ON LIVE CIRCUITS. AL- WAYS OBSERVE SAFETY PRECAUTIONS AND NEVER WORK ALONE. FAILURE TO OBSERVE THIS WARNING COULD RESULT IN SEVERE PERSONAL INJURY OR DEATH. NO Measure voltage at YES - Kf3lA 1 and K6lA2: - 24 VDC? Repair or Replace cable “46” NO Measure voltage at YES - K6lt. 3 and N2/OV, 0: - 24 VDC? * v Replace K6 NO Measure voltage at YES (PARAGRAPH 5.7) 7 N2/+ and N2/OV, 0: - 24 VDC? v , v Repair or Replace cable ‘43” NO Measure voltage at YES N2/J and N2/K. At idle: <IO VDC? At rated load: 10 - 20 VDC? Adjust or Repair N2 (PARAGRAPH 5. 14) Measure voltage at YES Xl/J2 and Xi/+@. At idle: <IO VDC? At rated - load: 10 - 20 VDC? v v Repair or Replace Continue on cables “76” and “77’ page 5 Figure 5-8 Generatorvoltage cannot be adjusted, or no voltage indication (sheet 4 of 7). 5-48