TM 9-6115-666-13
21. Place cover (30) on filter box FK (28) and install eight washers (31), eight serrated lock washers
(32), and screw eight screws (33) into filter box FK (28).
22. Install pickup cable (10) into back panel of control cabinet assembly (2), slide nut (9) over cable and
install onto cable union, connect cable on terminal strip (22) of speed governor N1 (23).
23. Install actuator cable (12) into back panel of control cabinet assembly (2), slide nut (13) over cable
and install onto cable union, connect cable on terminal strip (22) of speed governor N1 (23).
24. Close cable conduits below and beside speed governor assembly N1 (23) and swing digital isochro-
nous load sharing module N4 (16) back.
25. Install two nuts (18), two serrated lock washers (19), and two washers (20).
26. Install preheating assembly control cable (10) into back panel of control cabinet assembly (2), slide
nut (13) over cable and install onto cable union, connect cable on terminal strip X101 (24) on pre-
heating control board (25).
27. Install three heat sinks (71), six cables (70), three washers (72), three serrated lock washers (73),
and screw three nuts (74) onto terminals of load contactor K1 (69).
28. Install upper covers on busbar and close cable conduit above and beside load contactor K1 (69).
29. Place cover (39) on control cabinet assembly (2) and install two screws (34), two washers (35), two
washers (36), two serrated lock-washers (37), and two nuts (38).
30. Close control cabinet connection panel (5).
31. Secure control cabinet connection panel (5) with eighteen bolts (8), eighteen serrated lockwashers
(7), and eighteen washers (6).
32. Stow prop (4) and close front panel (3).
33. For installation of unit hood assembly (1) refer to paragraph 4.14.
4 - 1 1 0