TM 9-6115-668-13WARNINGThis procedure requires the aid of two assistants and a sling liftingdevice to prevent severe personal Injury.To prevent Injury from contact with filter box FK, wear gloves whenunscrewing nuts from the corrugated hoses.22. Remove nut (53) from corrugated hose (81) and remove from cables.23. Remove nut (64), serrated lock washer (65), washer (66), and generator cable 80 (67) from loadcontactor K1 (69).24. Remove nut (68) from corrugated hose (79) and remove from cables.25. Remove nut (54), serrated lock washer (55), washer (56) and generator cable 78 (57) from loadcontactor K1 (69).26. Remove nut (58) from corrugated hose (80) and remove from cables.27. Remove nut (59), serrated lock washer (60), washer (61) and generator cable 79 (62) from loadcontactor K1 (69).28. Remove nut (63) from corrugated hose (78) and remove from cables.29. Remove nut (45), serrated lock washer (44), washers (41, 43), and grounding strap (42) fromthreaded pin (40) on control cabinet unit (2).30. Remove eight bolts (77) from shock absorbers (76).31. Place sling around control cabinet assembly (2), being careful that sling is positioned between con-trol cabinet connection panel (5) and control cabinet (2) and attach to hoisting device.WARNINGStay clear of the suspended load.CAUTIONCare must be taken to ensure cables and cable ends do not snag orbecome damaged during lifting.32. Lift control cabinet assembly (2) gently off base frame (75) with one assistant feeding all cablesthrough the back of the control cabinet (2).33. When cables are free of the control panel (2) lift control panel completely off unit and set on a flatsurface or mounting.4 - 1 0 6