TM 9-6115-660-13&PNO.123456789NOTES:1.2.3.4.5.PARTS LISTPARTQUANTITYNO.REQUIREDDESCRIPTIONM22759/16-16-9ARWIRE, ELECTRICAL, 16 AWG, WHITEMS25036-10670TERMINAL LUG, CRIMP STYLE, INSULATED, 16-14 AWG TERMINAL SIZE, .138 STUD SIZEMS25036-1109TERMINAL LUG, CRIMP STYLE, INSULATED, 16-14AWG TERMINAL SIZE, .375 STUD SIZEMS25036-1554TERMINAL LUG, CRIMP STYLE, INSULATED, 16-14AWG TERMINAL SIZE, .500 STUD SIZESn60Pb40ARSOLDERMS3367-4-9ARSTRAP, TIEDOWNM23053/5-107-41INSULATION SLEEVING, .375 ID X 1.50 LMS25036-1081TERMINAL LUG, CRIMP STYLE, INSULATED, 16-14 AWG TERMINAL SIZE, .190 STUD SIZEMS23053/5-105-4l04 INSULATION SLEEVING, .187 ID X L AS REQUIREDQQ-S-571MIL-I-23053/5BUNDLE WIRE HARNESS AT EACH BREAKOUT AND AT 3.00 MAX INTERVALS USING TIEDOWN STRAP, FINDNO.6.HOT STAMP "97403-13229E5831" IN ACCORDANCE WITH MIL-M-60903 ON SLEEVING FIND NO. 3.EACH WIRE SHALL BE IDENTIFIED BY HOT STAMPING ADDRESS DESIGNATIONS USING .09-.16 HIGHBLACK CHARACTERS ON INSULATION SLEEVING, FIND NO.9, IN ACCORDANCE WITH MIL-M-60903.ATTACH WITHIN TWO INCHES OF BOTH END TERMINATIONS. APPROPRIATE ADDRESS SHALL CONSISTOF THE FROM TERMINATION, A DOUBLE HEADED ARROW AND THE TO TERMINATION.STRIP AND TIN WIRES IN ACCORDANCE WITH MIL-STD-2000, USING SOLDER, FIND NO. 5.CRIMPED CONNECTIONS SHALL BE IN ACCORDANCE WITH MIL-STD-454, REQUIREMENT 19.Figure G-3. Switch Box Harness Assembly W9 (Sheet 3).G-7
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business