TM 9-6115-660-13&P
NOTES:
1.
2.
3.
CRIMPED CONNECTIONS SHALL BE IN ACCORDANCE WITH MIL-STD-454, REQUIREMENT 19.
HOT STAMP LEGEND A, INDICATED IN TABULATION, USING .09-.16 HIGH BLACK CHARACTERS, IN TWO
PLACES (180° APART) ON INSULATION SLEEVING, FIND NO. 4, IN ACCORDANCE WITH MIL-M-60903, WITHIN
2.50 INCHES OF TERMINAL LUG.
HOT STAMP LEGEND B, INDICATED IN TABULATION, AND 97403-13229E5828- WITH APPROPRIATE DASH
NUMBER 2 ON INSULATION, FIND No. 4, IN ACCORDANCE WITH MIL-M-60903. LOCATE APPROXIMATELY AT
CENTER OF LEAD.
DIMENSIONS
MARKING
DASH
DIMENSION A
NO.
+/- 0.50
LEGEND A
LEGEND B
-1
16.00
K1-A1 - L1
W3
-2
18.00
K1-B1 - L2
W4
-3
23.00
K1-C1 -L3
W5
-4
12.00
K1-C1 - K2-C1
W6
-5
12.00
K1-B1 - K2-B1
W7
-6
12.00
K1-A1 - K2-A1
W8
PARTS LIST
Figure G-1. Electrical Leads W3, W4, W5, W6, W7, and W8.
G-2