TM 9-6115-660-13&PTESTRemove lens (1, figure 4-15) and bulb (2) and measure for continuity between terminals (8). If continuityexists, replace lamp housing.REMOVALNOTEThe switch box has three synchronizing lights.the same for each synchronizing lights.Replacement procedures are1. Cut and remove insulation sleeving (7) from both leads (6).2. Tag leads (6) and unsolder.3. Remove mounting nut (12), internal tooth lock washer (11), and housing body (5).INSTALLATION1.2.3.4.5.6.7.8.Position rubber gaskets (3 and 9) against mounting collar (4). If necessary, turn mounting collar (4)until proper amount of threads are exposed for installation of lens (1).Insert housing body (5) through opening in switch box cover (10).Place internal tooth lock washer (11) on housing body (5).Install mounting nut (12) on housing body (5). Tighten mounting nut (12) so that rubber gasket (9)seats firmly against switch box (10).Install insulation sleeving (7) on each wire (6).Solder tagged wires (6) to housing terminals (8).Install lamp (2) into housing body (5).Make sure that rubber gasket (3) is in place against mounting collar (4) and install lens (1) on housingbody (5).4-31