TM 9-6115-659-13&P6. Refer to table 5-1 and tag and disconnect all W9 wires from terminal board TB1 and TB2.7. Refer to table 5-1 and wiring diagram (figure FO-1), and tag and disconnect all W9 wires fromswitches S1, S2, and S10; indicator light housings XDS1 through XDS7; and permissive parallelingrelay PP.8. Remove switch box wiring harness W9 from switch box.Refer to figure G3, appendix G.INSTALLATION1.2.3.4.5.6.7.8.9.10.Position harness in switch box.Using figures 5-8 and figure FO-1 as a reference, connect wires to switches S1, S2, and S10; indicatorlight housings XDS1-XDS7; and permissive paralleling relay PP.Refer to table 5-1 and connect all W9 leads to terminal boards TB-1 and TB-2.Position relay board (4, figure 5-13) and install four flat washers (3), lock washers (2), and screws (1).Install W9 harness leads (3, figure 5-12), internal tooth washer (2), and nut (1) on load terminals L0and L3 (4).Place insulation sleeving on leads W9-20 and W9-49 and solder leads to resistor R3.Slide sleeving over solder joint and heat shrink.Refer to table 5-1 and install W9 wires (7, figure 5-11), flat washers (6), lock washers (5), and nuts (4)on contactor terminals (9).Refer to table 5-1 and install W9 leads (12) on terminals (13) using screws (11).Install contactor shield (3), two lock washers (2), and screws (1) over contactor terminals A2, B2,and C2.5-23