TM 9-6115-659-13&P
Section VII. ADMINISTRATIVE STORAGE
4-28 ADMINISTRATIVE STORAGE.
4-28.1 Short Term Storage. This type of storage is used when the power plant/power unit is expected
to be stored from 1 to 45 days. The storage may be at destination after domestic shipment, or may be
administrative storage when there is a shortage of maintenance manpower. For administrative storage:
a.
Perform current maintenance services and serviceability criteria evaluations before placing power
plant/power unit in administrative storage. Correct shortcomings and deficiencies and check that
all modification work orders have been applied.
b.
If possible, select an inside storage site. If inside storage is not available, a truck, van, conex
container, or other container may be used.
c.
When in administrative storage, the power plant/power unit should be capable of being made
mission ready within 24 hours unless a different time frame is directed by the approving authority.
4-28.2 Intermediate Term Storage. This type of storage is used when the power plant/power unit is
expected to be stored from 45 to 180 days.
4-28.3 Long Term Storage. This type of storage is used when the power plant/power unit is expected to
be stored for more than 180 days.
4-60