TM 9-6115-658-13&P
F-7
NOTES:
1. INSTALLED CRIMRED CONNECTIONS SHALL WITHSTAND AN AXIAL LOAD OF 8
POUNDS, SHALL HAVE CONTINUITY, AND SHALL SHOW NO EVIDENCE OF DAMAGE
OR ARCING WHEN CRIMPED WITH TERMINAL MANUFACTURERS RECOMMENDED
CRIMPING TOOL.
2. AT GENERATOR END OF CABLE, THE CONDUCTORS SHALL BE STRIPPED 1.00 FROM
END, AND SHALL HAVE THEIR INDIVIDUAL STRANDS TWISTED TOGETHER STARTING
AT THE JACKET. CONDUCTORS SHALL BE SOLDER COATED FOR A LENGTH OF .25 +
.12 FROM END, IN ACCORDANCE WITH MANUFACTURER COMMERCIAL PRACTICES.
3. INSULATION COLORS, IN ACCORDANCE WITH WIRE TABLE, SHALL BE INCLUDED AS
PART OF THE ORDERING DATA.
4. HOT STAMP 97403-13230E6954 WITH APPROPRIATE DASH NO. AND W[ ] NUMBER
IN .12 MIN HIGH BLACK CHARACTERS ON INSULATION SLEEVING, FIND NO. 2. HOT-
STAMPED MARKING SHALL PROVIDE VISUAL CONTRAST AND SHALL BE IMPRESSED
TO A DEPTH NOT EXCEEDING ONE-FOURTH THE THICKNESS OF MATERIAL FOR
PERMANENCY AND LEGIBILITY.
5. HOT STAMP TERMINAL DESIGNATION AS SHOWN IN WIRE TABLE, USING .09-.16 HIGH
CHARACTERS, ON INSULATION SLEEVING, FIND NO. 3 HOT-STAMPED MARKING
SHALL PROVIDE VISUAL CONTRAST AND SHALL BE IMPRESSED TO A DEPTH NOT
EXCEEDING ONE-FOURTH THE THICKNESS OF MATERIAL FOR PERMANENCY AND
LEGIBILITY.
WIRE LIST
TERMINATION
TERMINATION
DASH NO.
WIRE NO.
FROM
FIND
NO.
TO
FIND NO.
WIRE
COLOR
AWG
(REF)
-1
1
G1-L1
-
K1-A2
4
BLK
10
-1
2
G2-L2
-
K1-B1
4
RED
10
-1
3
G1-N
-
N
5
WHT
10
-1
4
G1-GND
-
GND
5
GRN
10
-2
1
G2-L1
-
K2-A2
4
BLK
10
-2
2
G2-L2
-
K2-B2
4
RED
10
-2
3
G2-N
-
N
5
WHT
10
-2
4
G2-GND
-
GND
5
GRN
10