ARMY TM 9-6115-464-12AIR FORCE TO 35C2-3-445-1NAVY NAVFAC P-8-624-12Table 5-3. Operator Troubleshooting For Fuel Burning Winterization KitNOTEBefore you use this table, make sure you have performed your PMCS.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION1. PRESS-TO-TEST INDICATOR DOES NOT LIGHT WHEN PRESSED.Circuit breaker open.Reset circuit breaker (para 2-22).2. HEATER CONTROL SWITCH PLACED IN ON POSITION BUT HEATER DOES NOT START.Circuit breaker open.Reset circuit breaker (para 2-22).3. BLOWER OPERATES BUT HEATER DOES NOT IGNITE.Step 1. Heater fuel shutoff valve closed.Open fuel shutoff valve (para 2-22).Step 2. Generator set fuel supply exhausted.Service generator set fuel supply (para 3-45).4. SURGING HEATER COMBUSTION.Restriction in fuel line.Locate and remove restriction in fuel line.5. FAN CONTINUES TO OPERATE AFTER PURGE CYCLE.Incorrect wiring connections.Check wiring for improper connections. Correct as necessary.5-15