ARMY TM 9-6115-464-12
AIR FORCE TO 35C2-3-445-1
NAVY NAVFAC P-8-624-12
4-15
SLAVE RECEPTACLE.
a.
Removal.
(1) Tag and disconnect electrical leads to the slave receptacle.
(2) Remove nuts (1, Figure 4-3), screws(2) and washes (3) to remove slave receptacle (4).
b. Cleaning and Inspection.
(1) Clean receptacle with filtered compressed air and a soft bristle brush.
(2) Clean receptacle box with a clean, lint-free cloth moistened with an approved solvent.
(3) Inspect receptacle for bent or broken pins, stripped terminal threads, corrosion or other damage.
(4) Inspect wiring of receptacle for frayed or deteriorated insulation, evidence of shorting and other damage.
(5) Inspect receptacle box for dents, corrosion and other damage.
(6) Replace any parts damaged beyond simple repair.
c.
Installation.
(1) Install slave receptacle (4), washers (3), screws (2), and nuts (1, Figure 4-3).
(2) Untag and reconnect electrical leads to the slave receptacle.
4-16 STARTER ASSEMBLY.
a.
Removal.
(1) Tag and disconnect electrical leads to starter assembly (Figure 4-4).
(2) Remove three bolts and lockwashers to remove starter from bell housing.
b. Cleaning and Inspection.
(1) Clean starter assembly with a clean, lint-free cloth moistened with an approved solvent.
(2) Inspect starter assembly for cracks, corrosion, evidence of shorting and other damage.
(3) Inspect solenoid assembly for cracks, corrosion, evidence of shorting and other damage.
(4) Inspect all threaded parts for stripped or damaged threads.
c.
Repair.
(1) Brush replacement.
NOTE
It is not necessary to remove the starter assembly from the engine to replace the
brushes.
(a)
(b)
(c)
(d)
(e)
(f)
Remove screws (1, Figure 4-5), and lockwashers (2)
Carefully remove commutator end frame assembly (3) and O-ring (4). Remove pipe plug (5)
and oil wick (6) from end frame (7).
Remove screws (8 and 12) and lockwashers (9 and 13) to remove electrical leads (10 and 14)
and brushes (11 and 15).
Remove brushholder pin (17) to remove brushholder spring (18) and brushholders (19 and 20)
from brush support.
Clean commutator end frame, brush support, brushholders, and brushholder springs in an approved
solvent and dry thoroughly.
Soak oil wick in a small container of approved cleaning solvent to remove oil. Remove from container,
squeeze out excess solvent and allow to air dry.
4-21