TM5-6115-634-14&P
NAVFAC P-8-647-14&P
T0-35C2-3-445-14
TM-6115-14&P/1
MAINTENANCE OF CONNECTOR PLATE
4-17.
REPLACE CONNECTOR PLATE
This task covers: a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
Reference
Para. 4-9 General Instructions.
Tools
General Mechanics Tool Kit
5180-00-177-7033
Materials/Parts
Connector Plate
97403-13228E1902
NOTE
Replacement of the connector
plate requires removal of
the mounted cable heads and
generator ground.
Proceed
is follows:
REMOVAL
1.
2.
OPEN LEFT REAR ACCESS DOOR.
Open door access, left rear on
generator set, to allow easy
access to rear of connector
plate.
REMOVE GROUND CABLE.
a.
Remove brass nut (1), self-
locking.
b.
Tag and remove ground wires
(3) and three flat washers
(2).
4-21